Ventricular catheter exchange using a peel-away outer catheter.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 21599450.
- Also identified by DOI 10.3171/2011.4.JNS091879.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Ventricular catheter replacement can be challenging, especially in patients with small ventricles. Shunt malfunction due to ventricular catheter obstruction can occur without ventricular enlargement, such as in the setting of slit-ventricle syndrome or benign intracranial hypertension. The authors describe a simple technique for ventricular catheter exchange using a peel-away catheter. In the limited initial experience of the senior author (G.S.C.), this technique appears to be safe and effective. To the authors' knowledge, this method has not been described in the neurosurgical literature before.
Medical subject headings
- Cerebral Ventricles
- Hydrocephalus
- Ventriculoperitoneal Shunt