Two-ply biodegradable nerve guide: basic aspects of design, construction and biological performance.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 2166595.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A synthetic biodegradable nerve guide was constructed of two polymeric layers: an inner microporous layer prepared from a copolymer of L-lactide and epsilon-caprolactone (pore size range 0.5-1 micron) and an outer microporous layer prepared from a polyurethane/poly(L-lactide) mixture (pore size range 30-70 microns). This nerve guide was used to bridge a 7 mm gap in the right sciatic nerve of rats. It enabled the sciatic nerve to regenerate across the gap, forming a new, well-defined nerve that effectively re-established the contact between the proximial and distal nerve end, as effective as an autograft.
Medical subject headings
- Nerve Regeneration
- Polymers
- Prostheses and Implants