Automated multi-level pathology identification techniques for abnormal retinal images using artificial neural networks.

Anitha, J; Vijila, C Kezi Selva; Selvakumar, A Immanuel; Indumathy, A; Jude Hemanth, D · Br J Ophthalmol · 2012

Where this comes from

Abstract

To automatically classify abnormal retinal images from four different categories using artificial neural networks with a high degree of accuracy in minimal time to assist the ophthalmologist in subsequent treatment planning. We used 420 abnormal retinal images from four different categories (non-proliferative diabetic retinopathy, central retinal vein occlusion, central serous retinopathy and central neo-vascularisation membrane). Green channel extraction, histogram equalisation and median filtering were used as image pre-processing techniques, followed by texture-based feature extraction. The application of Kohonen neural networks for pathology identification was also explored. The approach described yielded an average classification accuracy of 97.7% with ±0.8% deviation for individual categories. The average sensitivity and the specificity values are 96% and 98%, respectively. The time taken by the Kohonen neural network to achieve these accurate results was 300±40 s for the 420 images. This study suggests that the approach described can act as a diagnostic tool for retinal disease identification. Simultaneous multi-level classification of abnormal images is possible with high accuracy using artificial neural networks. The results also suggest that the approach is time-efficient, which is essential for ophthalmologic applications.