A model for evaluation of gas exchange: mouth to mouth ventilation of infants by emergency medical technicians.
other · Level V
Where this comes from
- Record sourced from PubMed, PMID 2174185.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We describe a model for evaluating techniques of infant ventilation during resuscitation. The utility of the model is illustrated by testing performance of emergency medical technicians in mouth to mouth ventilation of a model 4 kg infant. Ventilation was generally adequate with mean (+/- S.D.) frequency 22 +/- 9 breaths per minute and tidal volume 40 +/- 13 ml. Gas delivered to the model consisted of PICO2 7 +/- 6 mmHg and FIO2 0.20 +/- 0.007. Assuming normal metabolic rate and respiratory dead space, alveolar gas composition resulting from the simulated resuscitations would be PACO2 = 31 +/- 20 and PAO2 = 110 +/- 19 mmHg. Nine of ten rescuers would have achieved satisfactory PACO2 less than or equal to 50 and PAO2 greater than or equal to 100. However, the rescuers' exhaled oxygen concentration is not adequate to correct hypoxemia if associated with hypoventilation or a wide alveolar to arterial oxygen gradient.
Medical subject headings
- Emergency Medical Technicians
- Models, Biological
- Pulmonary Gas Exchange
- Resuscitation