Rex shunt preoperative imaging: diagnostic capability of imaging modalities.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 21765956.
- Also identified by DOI 10.1371/journal.pone.0022222 and PMC identifier PMC3134475.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this study was to evaluate the diagnostic capability of imaging modalities used for preoperative mesenteric-left portal bypass ("Rex shunt") planning. Twenty patients with extrahepatic portal vein thrombosis underwent 57 preoperative planning abdominal imaging studies. Two readers retrospectively reviewed these studies for an ability to confidently determine left portal vein (PV) patency, superior mesenteric vein (SMV) patency, and intrahepatic left and right PV contiguity. In this study, computed tomographic arterial portography allowed for confident characterization of left PV patency, SMV patency and left and right PV continuity in 100% of the examinations. Single phase contrast-enhanced CT, multi-phase contrast-enhanced CT, multiphase contrast-enhanced MRI, and transarterial portography answered all key diagnostic questions in 33%, 30%, 0% and 8% of the examinations, respectively. In conclusion, of the variety of imaging modalities that have been employed for Rex shunt preoperative planning, computed tomographic arterial portography most reliably allows for assessment of left PV patency, SMV patency, and left and right PV contiguity in a single study.