Management of hematocervix after loop electrosurgical excision procedure.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 21768861.
- Also identified by DOI 10.1097/AOG.0b013e3182234f5e.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Management is not established for the uncommon complication of cervical stenosis secondary to a loop electrosurgical excision procedure resulting in a hematocervix. A premenopausal woman underwent an electrosurgical procedure performed without complications and subsequently developed amenorrhea. The patient was determined to have developed a hematocervix secondary to the electrosurgical procedure. Increasingly aggressive methods were attempted to drain the hematocervix, finally with successful drainage being accomplished with the use of a manual vacuum aspirator. A catheter was then used to maintain patency of the cervical canal as it re-epithelialized. Manual vacuum aspiration and placement of a catheter to allow for re-epithelialization is a successful strategy to deal with hematocervix caused by electrosurgical procedures.
Medical subject headings
- Conization
- Electrosurgery
- Hematometra