Republished error management: Paediatric dosing errors before and after electronic prescribing.

Jani, Yogini Hariprasad; Barber, Nick; Wong, Ian Chi Kei · Postgrad Med J · 2011

cross_sectional · Level IV

Where this comes from

Abstract

To compare the incidence and severity rating of dose prescribing errors before and after the implementation of a commercially available electronic prescribing system at a tertiary care children's hospital. Dose errors were identified using prescription review to detect errors. Severity rating was determined by five judges using a validated, reliable scoring tool. The mean score for each error was used as an index of severity. Dose prescribing errors occurred in 88 of the 3939 (2.2%) items prescribed for outpatients and inpatients, and on discharge prescriptions prior to the implementation of electronic prescribing (EP). After EP, there were 57 dose errors in 4784 (1.2%) items prescribed (1% absolute reduction (p<0.001 χ(2) test; 95% CI of difference in proportions -1.6% to -0.5%)). A decrease in the severity rating of dose errors was also seen: dose errors with potentially minor outcomes 35/3939 (0.89%) pre vs 21/4784 (0.44%) post (95% CI of difference in proportions -0.8% to -0.11%, p=0.009 χ(2) test); moderate outcome 46/3939 (1.17%) pre vs 33/4784 (0.69%) post (95% CI of difference in proportions -0.91% to -0.08, p=0.019, χ(2) test); severe outcome: 7/3939 (0.18%) pre vs 3/4784 (0.06%) post (95% CI of difference in proportions -0.31% to +0.04, p=0.11, χ(2) test). Electronic prescribing appears to reduce rates of dosing errors in paediatrics, but larger studies are required to assess the effect on the severity of these errors and in different settings.