Accuracy and variability of right ventricular volumes and mass assessed by dual-source computed tomography: influence of slice orientation in comparison to magnetic resonance imaging.

Jensen, Christoph J; Wolf, Alexander; Eberle, Holger C; Forsting, Michael; Nassenstein, Kai; Lauenstein, Thomas C; Sabin, Georg V; Bruder, Oliver et al. · Eur Radiol · 2011

Level III

Where this comes from

Abstract

To evaluate the accuracy and variability of right ventricular (RV) volumes and mass using dual-source computed tomography (DSCT) and the influence of slice orientation in comparison to cardiac magnetic resonance imaging (CMR). In 33 patients undergoing cardiac DSCT and CMR, RV parameters were calculated using the short-axis (DSCT, CMR) and axial orientation (DSCT). Intra- and interobserver variability were assessed by Bland-Altman analysis. Short-axis orientation: RV parameters of the two techniques were not statistically different. Axial orientation: RV volumes and mass were significantly overestimated compared with short-axis parameters whereas EF was similar. The short-axis approach resulted in low variability, although the axial orientation had the least amount of intra- and interobserver variability. RV parameters can be more accurately assessed by DSCT compared with CMR using short-axis slice orientation. RV volumes and mass are significantly higher using axial compared with short-axis slices, whereas EF is unaffected. RV parameters derived from both approaches yield high reproducibility.

Medical subject headings