Restoring anterior leaflet continuity: the Spinnaker repair of Ebstein's anomaly.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 21801944.
- Also identified by DOI 10.1016/j.athoracsur.2011.03.016.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Several repair techniques for Ebstein's anomaly include aggressive mobilization of the anterior leaflet and the construction of a monobicuspid valve coapting against the interventricular septum. This can prove difficult when leaflet tissue is of poor quality or several fenestrations reduce leaflet surface. We present a simple and highly reproducible technique for restoring tissue continuity of the anterior leaflet that could represent a possible addendum to the existing array of surgical solutions. Two surgical cases are described. Both patients showed good valve function and trivial tricuspid regurgitation at short-term follow-up.
Medical subject headings
- Cardiac Valve Annuloplasty
- Ebstein Anomaly
- Pericardium
- Suture Techniques
- Tricuspid Valve
- Tricuspid Valve Insufficiency