Reduction of the risk of recurring heart failure events with cardiac resynchronization therapy: MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy).
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 21816309.
- Also identified by DOI 10.1016/j.jacc.2011.04.024.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The evaluation of the risk of recurring heart failure events (HFEs) was a pre-specified substudy of MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy). There are limited data regarding the effect of cardiac resynchronization therapy with a defibrillator (CRT-D) on the occurrence of recurring heart failure episodes after a first post-implantation HFE. Data with regard to recurring HFEs were prospectively collected for all 1,820 MADIT-CRT participants. The CRT-D versus defibrillator-only risk for nonfatal first- and subsequent-HFEs was assessed by Cox proportional hazards and Andersen-Gill proportional intensity regression modeling, respectively, in efficacy analyses recognizing active device-type during follow-up. Multivariate analysis showed that CRT-D was associated with a significant reduction in the risk of a first HFE (hazard ratio [HR]: 0.54, 95% confidence interval [CI]: 0.44 to 0.67, p < 0.001) and with a similar magnitude of reduction in the risk of HFEs subsequent to a first post-enrollment event (HR: 0.62, 95% CI: 0.45 to 0.85, p = 0.003). The benefit of CRT-D for the prevention of first and subsequent HFEs was pronounced among patients with left bundle branch block (HR: 0.38, 95% CI: 0.29 to 0.49, p < 0.001; and HR: 0.50, 95% CI: 0.33 to 0.76, p = 0.001, respectively) and nonsignificant in non-left bundle branch block patients (HR: 1.12, 95% CI: 0.77 to 1.64, p = 0.55; and HR: 0.99, 95% CI: 0.58 to 1.69, p = 0.96, respectively; p values for interaction: p < 0.001 and p = 0.06, respectively). The occurrences of first and second HFEs were associated with 7- and nearly 19-fold respective increases in the risk of subsequent mortality. In the MADIT-CRT trial, the benefit of cardiac resynchronization therapy for the reduction in recurring HFEs was maintained after the occurrence of a first post-enrollment event. The occurrence of HFEs greatly increased the risk of death. (Multicenter Automatic Defibrillator Implantation With Cardiac Resynchronization Therapy; NCT00180271).
Medical subject headings
- Cardiac Resynchronization Therapy
- Defibrillators, Implantable
- Heart Failure