After reverse shoulder arthroplasty (RSA) external and internal rotation will often remain restricted. A postoperative alteration of the biomechanics in the remaining cuff is discussed as a contributing factor to these functional deficits. In this study, muscle moment arms as well as origin-to-insertion distance (OID) were calculated using three-dimensional models of the shoulder derived from CT scans of seven cadaveric specimens. Moment arms for humeral rotation are significantly smaller for the cranial segments of SSC and all segments of TMIN in abduction angles of 30 degrees and above (p ≤ 0.05). Abduction moment arms were significantly decreased for all segments (p ≤ 0.002). OID was significantly smaller for all muscles at the 15 degree position (p ≤ 0.005), apart from the cranial SSC segment. Reduced rotational moment arms in conjunction with the decrease of OID may be a possible explanation for the clinically observed impaired external and internal rotation.