Quantitative assessment of nipple perfusion with near-infrared fluorescence imaging.
other · Level V
Where this comes from
- Record sourced from PubMed, PMID 21862913.
- Also identified by DOI 10.1097/SAP.0b013e31822f9af7 and PMC identifier 3224668.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Preserving the nipple-areolar complex with a nipple-sparing mastectomy improves cosmesis compared with skin-sparing mastectomy. However, complications such as necrosis of the nipple-areolar complex significantly affect cosmetic outcome. Many factors influence nipple-areolar perfusion, and no consensus currently exists on optimal incisional choice. This study evaluates 2 nipple-sparing mastectomy incision models using near-infrared fluorescence to assess perfusion quantitatively. The periareolar and radial incisions were compared with 2 control models in Yorkshire pigs (N = 6). Methylene blue and indocyanine green were injected intravenously, and near-infrared fluorescence images were recorded at 3 time points: before surgery, immediately after (0 hour), and 3 days postoperatively. Contrast-to-background ratio was used to assess perfusion. At 72 hours, radial incisions showed a statistically significantly higher perfusion compared with periareolar incisions (P < 0.05). Based on our findings, radial incisions for nipple-sparing mastectomy may be preferable due to higher perfusion; however, clinical trials are necessary for further assessment.
Medical subject headings
- Mastectomy
- Nipples
- Optical Imaging