Insertion of six different supraglottic airway devices whilst wearing chemical, biological, radiation, nuclear-personal protective equipment: a manikin study.

Castle, N; Pillay, Y; Spencer, N · Anaesthesia · 2011

cross_sectional · Level IV

Where this comes from

Abstract

Six different supraglottic airway devices: Combitube™, laryngeal mask airway, intubating laryngeal mask airway (Fastrach™), i-gel™, Laryngeal Tube™ and Pro-Seal™ laryngeal mask airway were assessed by 58 paramedic students for speed and ease of insertion in a manikin, whilst wearing either chemical, biological, radiation, nuclear-personal protective equipment (CBRN-PPE) or a standard uniform. All devices took significantly longer to insert when wearing CBRN-PPE compared with standard uniform (p < 0.001). In standard uniform, insertion time was shorter than 45 s in 90% of attempts for all devices except the Combitube, for which 90% of attempts were completed by 53 s. Whilst wearing CBRN-PPE the i-gel was the fastest device to insert with a mean (SD (95% CI)) insertion time of 19 (8 (17-21))s, p < 0.001, with the Combitube the slowest with mean (65 (23 (59-71))s. Wearing of CBRN-PPE has a negative impact on supraglottic airway insertion time.

Medical subject headings