Trochanteric fixation using a third-generation cable device--minimum follow-up of 3 years.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 21908164.
- Also identified by DOI 10.1016/j.arth.2011.06.032.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Third-generation trochanteric fixation cable systems are designed to overcome implant breakage, nonunion, and bony escape. The study prospectively assessed the functional and radiologic outcomes using such an implant. Forty-seven trochanteric fixations in 46 patients were performed over 4 years at 2 institutions using the Accord Cable Plate system (Smith and Nephew, Memphis, Tenn). Serial evaluation at a mean follow-up of 57 months demonstrated that the mean Harris hip scores improved from 52.3 preoperatively to 88.2 postoperatively (P < .001), and the mean pain score improved from 6.2 to 2.3, respectively (P < .001). No cable breakage, fretting, or fraying occurred. There were 2 cases of nonunion. A third-generation cable system appears to improve upon early-generation implants and provide favorable outcomes for reattachment of a trochanteric fragment in a variety of clinical scenarios.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Femur
Anatomy
- femur
- hip