An algorithm for the estimation of the signal-to-noise ratio in surface myoelectric signals generated during cyclic movements.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 21984489.
- Also identified by DOI 10.1109/TBME.2011.2170687.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
In many applications requiring the study of the surface myoelectric signal (SMES) acquired in dynamic conditions, it is essential to have a quantitative evaluation of the quality of the collected signals. When the activation pattern of a muscle has to be obtained by means of single- or double-threshold statistical detectors, the background noise level e (noise) of the signal is a necessary input parameter. Moreover, the detection strategy of double-threshold detectors may be properly tuned when the SNR and the duty cycle (DC) of the signal are known. The aim of this paper is to present an algorithm for the estimation of e (noise), SNR, and DC of an SMES collected during cyclic movements. The algorithm is validated on synthetic signals with statistical properties similar to those of SMES, as well as on more than 100 real signals.
Medical subject headings
- Algorithms
- Biological Clocks
- Electromyography
- Gait
- Movement
- Muscle Contraction
- Muscle, Skeletal