Intra-procedural aneurysm rupture treated with n-butyl cyanoacrylate embolization: technical note.

Patsalides, A; Smith, M; Gobin, Y P · J Neurointerv Surg · 2010

case_report · Level V

Where this comes from

Abstract

A case is described of utilizing liquid polymer and stent placement to treat a procedural rupture of intracranial aneurysm during coil embolization. Although this technique is challenging, it seals the rupture immediately and can be used when additional coil placement is not possible.