Standardization of metaiodobenzylguanidine heart to mediastinum ratio using a calibration phantom: effects of correction on normal databases and a multicentre study.
other
Where this comes from
- Record sourced from PubMed, PMID 22009380.
- Also identified by DOI 10.1007/s00259-011-1963-1.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This study was performed to demonstrate that the results obtained with a calibration phantom could be used as a tool for standardizing measurement of heart to mediastinum (H/M) ratio in cardiac metaiodobenzylguanidine (MIBG) imaging. Images of the phantom containing (123)I-MIBG were acquired on the cameras in 10 hospitals (11 camera types) to determine the relationship between H/M ratios using different collimators: low-energy (LE) and medium-energy (ME)/low-medium-energy (LME) collimators. The effect of standardization on the ME-comparable H/M ratio was examined in two settings: a Japanese standard MIBG database (n = 62) and multicentre studies (n = 49). In a multicentre study, probable Alzheimer's disease (AD, n = 18) and probable dementia with Lewy bodies (DLB, n = 31) were studied and standardized by the calibration phantom method. Linear regression equations between LE and ME collimators were obtained for the phantom study in all institutions. When the H/M ratio with an LE collimator was corrected based upon the calibration phantom, the corrected values were comparable to those obtained using ME collimators. The standard database also exhibited a normal distribution after standardization as determined by skewness and goodness-of-fit test. A mixture of the populations by LE and ME collimators showed significant separation of AD and DLB groups (F ratio = 24.9 for the late H/M), but the corrected values resulted in higher F ratios for both early and late H/M (F ratio = 34.9 for the late H/M). Standardization of H/M ratios by the heart-chest calibration phantom method is feasible among different collimator types. This method could be practically used for multicentre comparison of H/M ratios.
Medical subject headings
- 3-Iodobenzylguanidine
- Databases, Factual
- Mediastinum
- Myocardium
- Phantoms, Imaging
- Tomography, Emission-Computed, Single-Photon