Functional assessment of donor-site morbidity after harvest of a fibula chimeric flap with a sheet of soleus muscle for mandibular composite defect reconstruction.
case_control · Level III
Where this comes from
- Record sourced from PubMed, PMID 22113940.
- Also identified by DOI 10.1002/micr.20955.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This study aims to compare donor-site morbidity between the traditional fibula osteocutaneous and chimeric fibula flaps for mandibular reconstruction. Twenty-three patients with head and neck cancer were recruited. Fifteen patients underwent the traditional fibula osteocutaneous flap. Eight patients received a chimeric fibula osteocutaneous flap with a sheet of soleus muscle. Subjective donor-site morbidities were evaluated by questionnaire. Objective isokinetic testing and 6-minute walking test (6MWT) were used to evaluate ankle strength and walking ability. The results revealed no significant difference was found in total average score of the questionnaire between the traditional (2.57) and the chimeric (2.75) groups (P > 0.05). There were no significant differences in peak torque/total work of ankle motions and in walking ability at 6MWT between the traditional and chimeric groups (P > 0.05). In conclusion, compared with the traditional fibula osteocutaneous flap, the chimeric fibula flap does not increase donor-site morbidity for reconstructive surgery.
Medical subject headings
- Fibula
- Mandible
- Mouth Neoplasms
- Plastic Surgery Procedures
- Surgical Flaps
- Tissue and Organ Harvesting
- Tongue Neoplasms