Two-stage cementless revision of late total hip arthroplasty infection using a premanufactured spacer.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 22177795.
- Also identified by DOI 10.1016/j.arth.2011.10.022.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We observed 44 patients with 2-stage revisions for septic hip prostheses. We used a uniform protocol consisting of the implantation of a preformed spacer (interval 12-26 weeks), specific systemic antibiotic therapies, and cementless total hip arthroplasty at time of reimplantation. The minimum follow-up was 36 months (mean, 67 months; range, 36-120 months). During the spacer period, we observed 4 dislocations and 2 fractures leading to a resection arthroplasty interval before reimplantation in 5 cases. In one patient, reinfection was diagnosed 12 months after reimplantation. The Harris hip score increased from a preoperative mean of 39 to 90 at a mean follow-up of 67 months after reimplantation.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Hip Prosthesis
- Prosthesis Design
- Prosthesis-Related Infections
Anatomy
- hip