Percutaneous cerclage wiring for reduction of periprosthetic and difficult femoral fractures. A technical note.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 22192473.
- Also identified by DOI 10.1016/j.injury.2011.11.007.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Combining closed reduction techniques with minimally invasive plate osteosynthesis (MIPO) or intramedullary nailing is a technically challenging procedure, especially when dealing with complex femoral fractures such as periprosthetic fractures. Cerclage wiring is a well known adjunct for fracture reduction and fixation. However, it is usually performed by open reduction, requiring wide surgical exposures, that results in soft tissue stripping. To present how a novel cerclage wiring technique, employing a new percutaneous cerclage system, helped reduce a periprosthetic femoral fracture, fixed with MIPO, and a difficult proximal femoral fracture, stabilized with an intramedullary nail. Percutaneous wiring is an alternative reduction technique to facilitate the reduction and maintenance of difficult femoral fractures, which reduces the radiation exposure to the surgeon.
Medical subject headings
- Bone Plates
- Bone Wires
- Femoral Fractures
- Fracture Fixation, Internal