Cone beam CT for organs motion evaluation in pediatric abdominal neuroblastoma.
other
Where this comes from
- Record sourced from PubMed, PMID 22197353.
- Also identified by DOI 10.1016/j.radonc.2011.11.009.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To quantify the organ motion relative to bone in different breathing states in pediatric neuroblastoma using cone beam CT (CBCT) for better definition of the planning margins during abdominal IMRT. Forty-two datasets of kV CBCT for 9 pediatric patients with abdominal neuroblastoma treated with IMRT were evaluated. Organs positions on planning CT scan were considered the reference position against which organs and target motions were evaluated. The position of the kidneys and the liver was assessed in all scans. The target movement was evaluated in four patients who were treated for gross residual disease. The mean age of the patients was 4.1 ± 1.6 years. The range of target movement in the craniocaudal direction (CC) was 5mm. In the CC direction, the range of movement was 10mm for the right kidney, and 8mm for the left kidney. Similarly, the liver upper edge range of motion was 11 mm while the lower edge range of motion was 13 mm. With the use of daily CBCT we may be able to reduce the PTV margin. If CBCT is not used daily, a wider margin is needed.
Medical subject headings
- Abdominal Neoplasms
- Cone-Beam Computed Tomography
- Neuroblastoma
- Radiotherapy, Image-Guided