Evaluation of a wearable body monitoring device during treadmill walking and jogging in patients with fibromyalgia syndrome.

Munguía-Izquierdo, Diego; Santalla, Alfredo; Legaz-Arrese, Alejandro · Arch Phys Med Rehabil · 2012

cross_sectional · Level IV

Where this comes from

Abstract

To evaluate the reliability and validity of a body monitoring device against measures obtained from indirect calorimetry (IC) in patients with fibromyalgia syndrome (FMS) during various incremental exercise intensities. Cross-sectional reliability and validity study. Testing was completed in a university exercise physiology laboratory. Women (N=25) with FMS, with a mean age ± SD of 48.6±8.4 years and a median symptom duration of 15 years (25th-75th percentiles, 10-23y), were recruited to the study. Not applicable. Patients walked and jogged on a treadmill at 4 intensities (50m·min(-1), 0% grade [n=25]; 83.3m·min(-1), 0% grade [n=25]; 116.7m·min(-1), 0% grade [n=21]; 116.7m·min(-1), 2.5% grade [n=13]) during 2 measurement conditions, while IC and a multiple-sensor body monitor measured energy expenditure (EE). The differences between the readings (test 1 - test 2) and the SD of the differences, intraclass correlation coefficient (ICC), 95% confidence interval (CI) for the ICC, coefficient of repeatability, intrapatient SD, standard error of mean (SEM), minimal detectable change, Wilcoxon signed-rank test, and Bland-Altman graphs were used to examine reliability. The magnitude of the associations between IC and the body monitoring device, ICC, 95% CI for the ICC, paired t tests, and Bland-Altman graphs were used to examine the validity of the body monitoring device versus the IC. Moderate to excellent test-retest reliability was found for the 4 bouts of exercise (ICC=.73-.76). The SEM and minimal detectable change were satisfactory for the 4 bouts of exercise (.54-1.18kcal·min(-1) and 1.51-3.28kcal·min(-1), respectively). The differences mean between test and retest were lower than the SEM for the 4 bouts of exercise, varying from -.17 to .14kcal·min(-1). No significant differences were found between test and retest for any bout. The Bland-Altman plots and the coefficients of repeatability indicated that the differences between repeated tests would lie within 2 SDs in 95% of the cases for the 4 bouts of exercise. Significant associations were found between the body monitoring device and IC measurements of EE for the 4 bouts of exercise (r=.87-.99). The differences for all bouts between the 2 methods were nonsignificant, except for the second bout (P<.001). The ICCs and Bland-Altman plots of EE for the 4 bouts showed high agreement (ICCs=.84-.99) and sufficient accuracy for quantifying EE during exercise in patients with FMS. The body monitoring device provided a valid and reliable estimate of EE in patients with FMS during walking on horizontal and inclined surfaces in a laboratory setting across various exercise intensities.

Medical subject headings