Cementless acetabular fixation in patients 50 years and younger at 10 to 18 years of follow-up.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 22266047.
- Also identified by DOI 10.1016/j.arth.2011.10.020.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of the study was to evaluate the 10- to 18-year follow-up of cementless acetabular fixation in patients 50 years and younger. We retrospectively reviewed a consecutive group of 118 patients (144 hips) in whom primary total hip arthroplasty had been performed by 2 surgeons using a cementless acetabular component. Two (1.4%) cementless acetabular components were revised because of aseptic loosening. Twenty-four hips (16.7%) were revised for any mechanical failure of the acetabular component mostly related to acetabular liner wear and osteolysis. The average linear wear rate was 0.19 mm per year, which was higher than our previous reports with cemented acetabular fixation. The fiber mesh ingrowth surface of the cementless acetabular component in this study was superior to cemented acetabular components in terms of fixation. However, the high rates of wear and osteolysis have led to poor overall acetabular component construct survivorship.
Medical subject headings
- Acetabulum
- Arthroplasty, Replacement, Hip
- Bone Cements
- Femur Head Necrosis
- Hip Dislocation, Congenital
- Hip Prosthesis
- Osteoarthritis, Hip
Anatomy
- hip
- femur
- pelvis