A bad experience with endovascular treatment of an aortobronchial fistula.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 22269732.
- Also identified by DOI 10.1016/j.athoracsur.2011.07.031.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A 35-year-old woman presented with an aortobronchial fistula after polyester graft replacement of coarctation of the descending thoracic aortic. Treatment of the fistula included antibiotic therapy and stent graft placement. Life-threatening sepsis developed in the postoperative period. Subsequent treatment required excision of the infected graft complex with extra-anatomic reconstruction of the thoracic aorta. The patient had a very stormy postoperative course and required heroic measures, including mechanical circulatory support, to achieve survival. The present case demonstrates failure of endovascular therapy of an aortobronchial fistula. The case should serve as a cautious reminder that the underlying cause for infection remains even after apparent successful endovascular therapy.
Medical subject headings
- Aortic Diseases
- Blood Vessel Prosthesis
- Bronchial Fistula
- Endovascular Procedures
- Fistula
- Postoperative Complications
- Prosthesis-Related Infections
- Shock, Septic