Closed traumatic rupture of the ring finger flexor tendon pulley.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 2229971.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We report an unusual case of closed traumatic rupture of the ring finger flexor tendon pulley not previously reported in the literature. This injury occurred in a 21-year-old athlete during rockclimbing. Lack of flexion of the distal interphalangeal joint was accompanied by a palpable subcutaneous cord on the palmar side of the proximal phalanx. A simple repair of the pulley was done. The postoperative functional result was satisfactory.
Medical subject headings
- Athletic Injuries
- Finger Injuries