Transbronchial biopsies in children after heart-lung transplantation.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 2235222.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Sixty transbronchial biopsies have been performed in eight children after heart-lung transplantation. The selection of fiber-optic bronchoscope or a small (4 mm; 30 cm) rigid bronchoscope was made according to the size of endotracheal tube required at surgery. If the endotracheal tube was size 7.5 or greater, a fiber-optic bronchoscope was used, whereas if the endotracheal tube size was below 7, a rigid bronchoscope was used. For the diagnosis of lung rejection, the histology of biopsies revealed a sensitivity of 91% and specificity of 69% (similar to the result in adults). The histology also distinguished lung infection from rejection. Complications included three pneumothoraces and two clinically significant episodes of hemorrhage, one of which led to a cardiorespiratory arrest, which may have been caused by hypoxia. As a result, arterial oxygen saturation is now monitored during the procedure using a pulse oximeter.
Medical subject headings
- Bronchi
- Bronchoscopy
- Graft Rejection
- Heart-Lung Transplantation
- Lung Diseases
- Opportunistic Infections
- Pneumonia