A randomised prospective study of split skin graft donor site dressings: AWBAT-D™ vs. Duoderm®.

Solanki, N S; Mackie, I P; Greenwood, J E · Burns · 2012

rct · Level II

Where this comes from

Abstract

To assess patient comfort and wound-healing efficacy of a new, purpose-designed biosynthetic material (AWBAT-D™) in the healing of split-skin graft donor sites in comparison with our standard dressing, Duoderm(®). We conducted a prospective randomised controlled trial of donor site dressings, comparing AWBAT-D™ with our standard dressing, Duoderm(®). Patients were randomly allocated to have their donor site dressed with one of these materials. Outcome measures included pain scores at rest and during dressing changes, time to re-epithelialisation, time to discharge, scarring and infection. Results were assessed for significance using the Mann-Whitney U-test (non-parametric data) and the Chi-Square test (parametric data). Fourteen patients were recruited with 8 donor sites in each group. The mean pain scores at rest and during dressing changes were not found to be significantly different between the two groups (P=0.99 and P=0.90 respectively). The median time to re-epithelialisation was shorter in the Duoderm(®) group at 11 days compared to 17 days in the AWBAT-D™ group (P=0.007). The median time to discharge was not significantly different (P=0.38). No infection or scarring has been observed. Based on these early results, AWBAT-D™ appears to have slower donor site healing and does not provide significant improvements in postoperative pain or discharge time compared to Duoderm(®). There is no evidence at this stage that our standard donor site dressing should be changed.