Intraoperative prediction of postoperative flap outcome using the near-infrared fluorophore methylene blue.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 22395044.
- Also identified by DOI 10.1097/SAP.0b013e318236babe and PMC identifier 3371147.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Methylene blue (MB) is a near-infrared fluorophore that provides a stable visual map of skin perfusion after intravenous injection. We explored the capability of MB to predict submental flap postoperative outcome using a single intraoperative measurement. Submental flaps were created in N = 15 pigs and imaged using the FLARE imaging system immediately after surgery and at 72 hours. Using the first 3 pigs, optimal MB dosing was found to be 2.0 mg/kg. Training and validation sets of 6 pigs each were then used for receiver operating characteristic analysis. In the training set, a contrast-to-background ratio (CBR) threshold of 1.24 provided the highest sensitivity and specificity to predict tissue necrosis at 72 hours. In the validation set, this threshold provided a prediction sensitivity of 95.3% and a specificity of 98.0%. We demonstrate that a single intraoperative near-infrared measurement can predict submental flap outcome at 72 hours.
Medical subject headings
- Dermatologic Surgical Procedures
- Methylene Blue
- Monitoring, Intraoperative
- Optical Imaging
- Skin
- Surgical Flaps