Tibial stem tip pain in stemmed revision total knee arthroplasty: treatment with tension band plating.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 22397860.
- Also identified by DOI 10.1016/j.arth.2011.12.032.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The use of stemmed modular components in revision total knee arthroplasty has led to increasingly described pain located at the tip of the stem of the implant. This has been described in the literature as being due to the elastic modulus mismatch between the stem tip and the host bone. Current management is re-revision total knee arthroplasty in an attempt to alleviate the mismatch. This case report describes a novel technique using a dynamic compression plate acting as a tension band at the stem tip to successfully treat this condition.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Bone Plates
- Knee Prosthesis
- Reoperation
Anatomy
- knee
- tibia