Randomized trial of early bubble continuous positive airway pressure for very low birth weight infants.

Tapia, Jose L; Urzua, Soledad; Bancalari, Aldo; Meritano, Javier; Torres, Gabriela; Fabres, Jorge; Toro, Claudia A; Rivera, Fabiola et al. · J Pediatr · 2012

rct · Level II

Where this comes from

Abstract

To determine whether very low birth weight infants (VLBWIs), initially supported with continuous positive airway pressure (CPAP) and then selectively treated with the INSURE (intubation, surfactant, and extubation to CPAP; CPAP/INSURE) protocol, need less mechanical ventilation than those supported with supplemental oxygen, surfactant, and mechanical ventilation if required (Oxygen/mechanical ventilation [MV]). In a multicenter randomized controlled trial, spontaneously breathing VLBWIs weighing 800-1500 g were allocated to receive either therapy. In the CPAP/INSURE group, if respiratory distress syndrome (RDS) did not occur, CPAP was discontinued after 3-6 hours. If RDS developed and the fraction of inspired oxygen (FiO(2)) was >0.35, the INSURE protocol was indicated. Failure criteria included FiO(2) >0.60, severe apnea or respiratory acidosis, and receipt of more than 2 doses of surfactant. In the Oxygen/MV group, in the presence of RDS, supplemental oxygen without CPAP was given, and if FiO(2) was >0.35, surfactant and mechanical ventilation were provided. A total of 256 patients were randomized to either the CPAP/INSURE group (n = 131) or the Oxygen/MV group (n = 125). The need for mechanical ventilation was lower in the CPAP/INSURE group (29.8% vs 50.4%; P = .001), as was the use of surfactant (27.5% vs 46.4%; P = .002). There were no differences in death, pneumothorax, bronchopulmonary dysplasia, and other complications of prematurity between the 2 groups. CPAP and early selective INSURE reduced the need for mechanical ventilation and surfactant in VLBWIs without increasing morbidity and death. These results may be particularly relevant for resource-limited regions.

Medical subject headings