Case report: anterior mediastinal central line malposition.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 22415531.
- Also identified by DOI 10.1213/ANE.0b013e31824e2d37.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Central venous catheter (CVC) placement is a routine procedure in the management of critically ill patients. It is important to ensure correct positioning of the catheter tip just above the junction of the superior vena cava and the right atrium, to reduce associated complications and to optimize catheter function. The incidence of catheter misplacement is approximately 3%-4% for both subclavian and internal jugular vein access procedures. CVC placement in the right subclavian vein is associated with a higher risk of malposition.(1) We report an unexpected secondary malposition of a right subclavian CVC in the anterior mediastinum, with resultant vena caval perforation in a patient admitted to the neuro-critical care unit after undergoing a craniotomy procedure.
Medical subject headings
- Catheterization, Central Venous
- Central Venous Catheters
- Intraoperative Complications
- Mediastinum