Removal of trabecular metal osteonecrosis intervention implant and conversion to primary total hip arthroplasty.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 22425306.
- Also identified by DOI 10.1016/j.arth.2012.01.025.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Core decompression and placement of the Trabecular Metal Osteonecrosis Intervention Implant have shown to be initially successful in treating early osteonecrosis. When treatment fails, however, patients often undergo primary total hip arthroplasty (THA) requiring removal of a previously inserted trabecular metal implant. We describe a technical tip for removal of a well-ingrown trabecular metal screw. A metal-cutting trephine placed over the screw allows for removal in an efficient manner while minimizing additional dissection and bone loss during conversion to THA.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Bone Screws
- Device Removal
- Femur Head Necrosis
- Metals
- Prostheses and Implants
Anatomy
- femur
- hip