Tc-99m-MDP scintigraphy not informative in painful total hip arthroplasty.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 2243210.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
In 61 painful cemented total hip arthroplasties the diagnostic specificity was 0.7 for plain radiography and 0.46 for scintigraphy. The diagnostic sensitivity was 0.97 for radiography and 0.77 for scintigraphy. False negative radiology occurred in 0.05 and false positive in 0.23. False negative scintigraphy was encountered in 0.27 and false positive in 0.49. Seven of thirty-nine hips were operatively explored because of false positive scintigraphy. In conclusion, Tc-99m-MDP scintigraphy could not used as a complementary diagnostic measure in our hands.
Medical subject headings
- Hip Joint
- Hip Prosthesis
- Pain
- Technetium Tc 99m Medronate
Anatomy
- hip