Steady and pulsatile flow fields in an end-to-side arterial anastomosis model.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 2243410.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We investigated the flow field within a rigid-walled in vitro model of an end-to-side 45 degree anastomosis in an attempt to identify possible hemodynamic factors that may contribute to the pathogenesis of distal anastomotic intimal hyperplasia. A high-resolution photochromic tracer technique was used to visualize the flow in orthogonal planes and to determine the axial wall shear stress profiles for both steady and pulsatile flows over a range of physiologically relevant conditions. The flow field showed qualitative similarities to those seen in curved vessel: rapidly moving fluid from the graft section affects the bed of the host vessel, that is, the wall opposite the anastomosis, eventually advancing down the host vessel in a spiraling motion. A small mobile separation zone was noted at the toe of the anastomosis. Comparison of wall shear stress profiles with previously reported preferential sites for the development of intimal hyperplasia supported a low wall shear stress and/or flow separation pathogenesis hypothesis. One notable exception was the bed of the host artery that appeared to be subjected to a complex hemodynamic environment.
Medical subject headings
- Arteriovenous Shunt, Surgical
- Models, Cardiovascular
- Models, Structural
- Pulsatile Flow