Real time observation and kinetic modeling of the cellular uptake and removal of silicon quantum dots.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 22475529.
- Also identified by DOI 10.1016/j.biomaterials.2012.03.029.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The time courses of uptake and removal of silicon quantum dots (Si-QDs) by human umbilical endothelial cells (HUVECs) were observed via confocal laser scanning microscope. Si-QDs were internalized via endocytosis and transported to late endosomes/lysosomes. The number of internalized Si-QDs increased with time and gradually reached a plateau value. When Si-QD-internalized HUVECs were subsequently washed and exposed to fresh culture medium, HUVECs removed internalized Si-QDs via exocytosis. The number of internalized Si-QDs decreased with time and gradually reached a plateau value. Not all internalized Si-QDs were removed from the cell interior but large numbers of internalized Si-QDs remained accumulated inside cells. A kinetic model based on the mass balance of Si-QDs and receptors in a cell was proposed to describe the cellular uptake and removal of Si-QDs. Model calculation fitted well with experimental results. Using this model, the dissociation constant between receptors and Si-QDs in the endosome, K(d,in), was found to be a determinant factor for Si-QD accumulation in cells after the removal process.
Medical subject headings
- Quantum Dots
- Silicon