Prone accelerated partial breast irradiation after breast-conserving surgery: compliance to the dosimetry requirements of RTOG-0413.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 22543213.
- Also identified by DOI 10.1016/j.ijrobp.2012.01.055.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The dosimetric results from our institution's trials of prone accelerated partial breast irradiation are compared with the dosimetric requirements of RTOG-0413. Trial 1 and Trial 2 are 2 consecutive trials of prone-accelerated partial breast irradiation. Eligible for both trials were stage I breast cancer patients with negative margins after breast-conserving surgery. The planning target tumor volume (PTV) was created by extending the surgical cavity 2.0 cm for Trial 1 and 1.5 cm for Trial 2, respectively. Contralateral breast, heart, lungs, and thyroid were contoured. Thirty Gray was delivered in five daily fractions of 6 Gy by a three-dimensional conformal radiation therapy technique in Trial 1 and were by image-guided radiation therapy/intensity-modulated radiation therapy in Trial 2. Dosimetric results from the trials are reported and compared with RTOG 0413 requirements. One hundred forty-six consecutive plans were analyzed: 67 left and 79 right breast cancers. The plans from the trials complied with the required>90% of prescribed dose covering 90% of PTV_EVAL (=generated from the PTV by cropping 0.5 cm from the skin edge and excluding the chest wall): V90% was 98.1±3.0% (with V100% and V95%, 89.4±12.8%, 96.4±5.1%, respectively). No significant difference between laterality was found (Student's t test). The dose constraints criteria of the RTOG-0413 protocol for ipsilateral and contralateral lung (V30<15% and Dmax<3%), heart (V5<40%), and thyroid (Dmax<3%) were satisfied because the plans showed an average V5% of 0.6% (range, 0-13.4) for heart, an average V30% of 0.6% (range, 0-9.1%) for ipsilateral lung, and <2% maximum dose to the thyroid. However, our partial breast irradiation plans demonstrated a higher dose to contralateral breast than that defined by RTOG constraints, with a median value of maximum doses of 4.1% (1.2 Gy), possibly as a result of contouring differences. Our technique for prone accelerated partial breast irradiation generally satisfied RTOG-0413 requirements.
Medical subject headings
- Breast Neoplasms
- Organs at Risk
- Patient Positioning
- Radiotherapy, Conformal