Results of anterior-inferior 2.7-mm dynamic compression plate fixation of midshaft clavicular fractures.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 22561745.
- Also identified by DOI 10.1097/BOT.0b013e318254883a.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate the outcome of operatively treated unstable displaced diaphyseal clavicle fractures with anterior-inferior 2.7-mm dynamic compression plate (DCP) fixation. Retrospective review of clavicle fractures. Level-1 trauma teaching center. One hundred twenty-nine clavicle fractures. An anterior-inferior approach to clavicle fractures was used with the application of a 2.7-mm DCPs. Radiographic assessment of healing and complication rates. One hundred twenty-five fractures healed (97%). Postoperative complications included 1 superficial wound problem, 3 deep wound problems, 5 nonunions, and 4 prominent implants requiring removal in 3. Anterior-inferior placement of 2.7-mm DCPs seems safe and is associated with minimal complications. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Medical subject headings
- Clavicle
- Fracture Fixation, Internal
- Fractures, Bone
Anatomy
- clavicle