Early stenosis of stentless aortic valve prosthesis: a word of caution.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 22595469.
- Also identified by DOI 10.1016/j.athoracsur.2012.01.066.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Early stenosis of stentless bioprosthetic valves is rarely reported. In this report, we discuss a 75-year-old woman who presented with signs of congestive heart failure 5 months after a stentless aortic valve replacement, complicated by postoperative heparin-induced thrombocytopenia. Intraoperative findings were highly unusual, consisting of a fibrous band in the subvalvular apparatus linking the interventricular septum to the free wall of the left ventricle, resulting in significant left ventricular outflow tract obstruction. The possible causes of the fibrous band are discussed.