Magnetic resonance imaging-based radiation-absorbed dose estimation of 166Ho microspheres in liver radioembolization.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 22633554.
- Also identified by DOI 10.1016/j.ijrobp.2011.12.085.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To investigate the potential of magnetic resonance imaging (MRI) for accurate assessment of the three-dimensional (166)Ho activity distribution to estimate radiation-absorbed dose distributions in (166)Ho-loaded poly (L-lactic acid) microsphere ((166)Ho-PLLA-MS) liver radioembolization. MRI, computed tomography (CT), and single photon emission CT (SPECT) experiments were conducted on an anthropomorphic gel phantom with tumor-simulating gel samples and on an excised human tumor-bearing liver, both containing known amounts of (166)Ho-PLLA-MS. Three-dimensional radiation-absorbed dose distributions were estimated at the voxel level by convolving the (166)Ho activity distribution, derived from quantitative MRI data, with a (166)Ho dose point-kernel generated by MCNP (Monte Carlo N-Particle transport code) and from Medical Internal Radiation Dose Pamphlet 17. MRI-based radiation-absorbed dose distributions were qualitatively compared with CT and autoradiography images and quantitatively compared with SPECT-based dose distributions. Both MRI- and SPECT-based activity estimations were validated against dose calibrator measurements. Evaluation on an anthropomorphic phantom showed that MRI enables accurate assessment of local (166)Ho-PLLA-MS mass and activity distributions, as supported by a regression coefficient of 1.05 and a correlation coefficient of 0.99, relating local MRI-based mass and activity calculations to reference values obtained with a dose calibrator. Estimated MRI-based radiation-absorbed dose distributions of (166)Ho-PLLA-MS in an ex vivo human liver visually showed high correspondence to SPECT-based radiation-absorbed dose distributions. Quantitative analysis revealed that the differences in local and total amounts of (166)Ho-PLLA-MS estimated by MRI, SPECT, and the dose calibrator were within 10%. Excellent agreement was observed between MRI- and SPECT-based dose-volume histograms. Quantitative MRI was demonstrated to provide accurate three-dimensional (166)Ho-PLLA-MS activity distributions, enabling localized intrahepatic radiation-absorbed dose estimation by convolution with a (166)Ho dose point-kernel for liver radioembolization treatment optimization and evaluation.
Medical subject headings
- Embolization, Therapeutic
- Holmium
- Lactic Acid
- Liver Neoplasms
- Magnetic Resonance Imaging
- Microspheres
- Polymers
- Radioisotopes