Introduction of an alternative standardized radiographic measurement method to evaluate volar angulation in subcapital fractures of the 5th metacarpal.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 22644541.
- Also identified by DOI 10.1007/s00256-012-1436-z.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of the present study was to compare the intra- and interobserver reliability of two different measurement methods for volar angulation of the 5th metacarpal (MC) in an attempt to establish a new standard measurement method to reduce interobserver discrepancies for therapeutic decisions. Twenty patients with subcapital fractures of the 5th MC were radiologically investigated. Imaging consisted of a radiographs in antero-posterior and precise lateral view in addition to a CT scan of the 5th MC. Measurement of volar angulation was accomplished using the conventional and the shaft articular surface (SAS) method. The measurements of five investigators were exported to a spreadsheet for statistical analysis to evaluate the intra-and interobserver reliability. The conventional technique showed large differences among the investigators and poor interobserver reliability (W = 0.328 and 0.307) both at injury (p = 0.001) and at follow-up (p = 0.189). The intraobserver concordance of all investigators showed better results with the SAS than with the conventional technique. With the SAS technique, no statistically significant difference among the investigators could be detected at either the time of injury (p = 0.418) or at follow-up (p = 0.526) with excellent interobserver reliability (W = 0.051 and W = 0.041). Evaluation of volar angulation at follow-up using CT scans did not show any statistically significant difference between the techniques with better correlation among the observers with the SAS technique (p = 0.838). The interobserver correlation of volar angulation with lateral radiographs using the conventional technique was insufficient. Therefore, we recommend the use of the novel SAS technique as standardized measurement method which showed higher accuracy and interobserver reliability in order to facilitate the choice of adequate treatment option. A CT scan should be performed in cases with ambivalent treatment options. Evidence-Based Medicine Level II.
Medical subject headings
- Capitate Bone
- Fractures, Bone
- Metacarpal Bones
- Palmar Plate
- Tomography, X-Ray Computed
Anatomy
- hand