A prospective comparison of rubidium-82 PET and thallium-201 SPECT myocardial perfusion imaging utilizing a single dipyridamole stress in the diagnosis of coronary artery disease.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 2266384.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of the present study is to prospectively compare myocardial perfusion imaging with rubidium-82 (82Rb) by positron emission tomography (PET) with thallium-201 (201Tl) imaging by single-photon emission tomography (SPECT) by recording both studies with a single dipyridamole handgrip stress, and reading both sets of images with the same display technique. In a series of 202 patients with previous coronary arteriography, the sensitivity, specificity, and accuracy of 82Rb PET were 93%, 78%, and 90% and for 201Tl SPECT 76%, 80%, and 77%, respectively. When 70 patients with previous therapeutic interventions were excluded, the remaining 132 patients showed a sensitivity, specificity, and accuracy of 95%, 82% and 92% for 82Rb PET and 79%, 76%, and 78% for 201Tl SPECT. The improved contrast resolution of PET resulted in markedly superior images and a more confident identification of defects.
Medical subject headings
- Coronary Circulation
- Coronary Disease
- Rubidium Radioisotopes
- Thallium Radioisotopes
- Tomography, Emission-Computed
- Tomography, Emission-Computed, Single-Photon