Double loop locking suture: a technique of tendon repair for early active mobilization. Part I: Evolution of technique and experimental study.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 2269789.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This article describes a technique of tendon repair and two variations using double loop locking sutures. Experimental study on human tendon specimens showed that the average tensile strength of tendon junctures was 4400 grams by double loop locking sutures and 2252 grams by Kessler's technique. The study also showed that the weakest point of the tendon juncture by double loop locking sutures was the sutures.
Medical subject headings
- Finger Injuries
- Suture Techniques