AAA with a challenging neck: early outcomes using the Endurant stent-graft system.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 22705160.
- Also identified by DOI 10.1016/j.ejvs.2012.04.031.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The efficacy and safety of endovascular aneurysm repair is disputable in aneurysms with a short, angulated, wide, conical, or thrombus-lined neck making a reliable seal difficult to achieve. The influence of a challenging neck on early results using the Endurant stent-graft system in high risk patients was investigated. A retrospective study conducted on a prospectively compiled database of 72 elective patients with challenging neck treated with the Endurant system (Endurant Stent Graft, Medtronic AVE, Santa Rosa, CA, USA). These patients were compared to a control group (n = 65) without significant neck problems. Endpoints were early technical and clinical success, deployment accuracy and differences in operative details at one month follow-up. Data are reported as mean and standard deviation or as absolute frequency and percentage (%). Normality distribution and homogeneity of variances were tested by Shapiro-Wilks and Levene tests, respectively. Inter-group comparisons for each variable were made by t-test or χ2-test or Fisher exact test. A p < 0.05 was considered statistically significant. Mean age was 76.12 years; 76.6% were males. Risk factors and pre-operative variables did not differ significantly between the two groups. Mean neck length was 10.56 mm in patients with challenging anatomies and 22.85 mm in controls. Patients with a challenging neck differed significantly (p < 0.001) from controls in terms of mean infrarenal (37.67° vs. 20.12°) and suprarenal angle (19.63° vs. 15.57°); 82% of patients with a challenging neck were ASA III/IV (vs. 86%). Technical success was 100%, with four unplanned proximal extension in challenging group. No type I endoleaks or aneurysm-related deaths occurred in either group; major complications were 1.54% vs. 1.39% (p = 0.942). Operative details were similar in both groups. Treatment with the Endurant stent-graft is technically feasible and safe, yielding satisfactory results even in challenging anatomies. Medium- and long-term data are needed to verify durability, but early results are promising.
Medical subject headings
- Aortic Aneurysm, Abdominal
- Blood Vessel Prosthesis
- Blood Vessel Prosthesis Implantation
- Endovascular Procedures
- Stents