A clove-hitch suture method for small-caliber tendon ends.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 22810401.
- Also identified by DOI 10.2106/JBJS.K.00414.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The choices of suture methods used to secure the end of a small-caliber tendon with a combination of suture materials passing through and looping around the tendon are not well documented. A secure stitch-tendon unit may be an important factor in preserving muscle function, by facilitating healing without gapping or failure. Five types of suture methods utilizing four or fewer passes through the tendon end were mechanically tested on 178 canine flexor digitorum profundus tendons. An Instron apparatus was used to test the load to failure. The single and double clove-hitch suture methods demonstrated improved repair strength when compared with the three other methods studied in this small-caliber canine tendon model. The single and double clove-hitch suture method better secured the end of a small-caliber tendon compared with other methods. The single (pull-out) and double (non-pull-out) clove-hitch suture methods are reliable alternatives for the repair of small-caliber tendons.
Medical subject headings
- Suture Techniques
- Tendon Injuries
- Tendon Transfer