A biomimetic mass-flow transducer utilizing all-optofluidic generation of self-digitized, pulse code-modulated optical pulse trains.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 22858863.
- Also identified by DOI 10.1039/c2lc40468k.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We present a new mass-flow transducer producing responses in the form of optical pulse trains that are encoded with information on the strength and position of the stimulus. We implemented the self-digitization and encoding capabilities all-optofluidically, without involving external electronics, by integrating one optical fiber cantilever with multiple polymer optical waveguides on a microfluidic platform. The transducer can also be configured to respond only to transitional stimuli. These features closely mimic the rate-coding, action potential labeling, and rapid adaptation processes observed in biological mechanoreceptors and allow multiple transducers to transmit signals over a single, shared channel. We fabricated the transducer using polymer-based soft-lithography techniques. Its characterization confirmed the stimulus strength-dependent generation of optical pulses and the feasibility of multiplexing 2(n-1) to 2(n) transducers using n waveguides.
Medical subject headings
- Biomimetics
- Microfluidic Analytical Techniques
- Optics and Photonics