Arthroscopic collagen meniscus implantation for partial lateral meniscal defects: a 2-year minimum follow-up study.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 22915481.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Loss of knee meniscal tissue often leads to increased pain and decreased function. At a minimum 2-year follow-up, patients receiving a lateral collagen meniscus implant (CMI) would show improved knee function and decreased pain compared with their preoperative status. Case series; Level of evidence, 4. Twenty-four patients with irreparable lateral meniscal tears (n = 7) or previous partial lateral meniscectomy (n = 17) underwent arthroscopic lateral collagen meniscus implantation. Clinical evaluation was performed preoperatively, at 6 months, and at a minimum 2-year follow-up with Lysholm, visual analog scale (VAS) for pain, Tegner, objective International Knee Documentation Committee (IKDC), and EuroQol 5 dimensions (EQ-5D) scores. A magnetic resonance imaging (MRI) evaluation was performed preoperatively and at final follow-up using the modified Yulish score for cartilage and the Genovese score for implant size and signal intensity. All clinical scores significantly improved from preoperative evaluation to final follow-up. Average Lysholm scores improved from 64.0 ± 16.2 to 92.7 ± 13.8 (P < .0001), VAS for pain from 55.2 ± 29.4 to 19.5 ± 25.6 (P < .0001), Tegner from 3 (interquartile range, 2-4) to 5 (interquartile range, 4-7) (P = .0062), objective IKDC from 6A, 14B, 4C to 20A, 3B, 1D (P = .0002), and EQ-5D from 0.58 ± 0.28 to 0.89 ± 0.14 (P < .0001). Good to excellent (A + B) objective IKDC scores improved from 83% preoperatively to 96% at 2-year follow-up. The Tegner index (the percentage of the lost activity level that was regained as a result of the treatment intervention) was 47% at 6-month follow-up and 79% at 2-year follow-up: this improvement was statistically significant (P = .0062). The MRI evaluations for tibial and femoral modified Yulish scores for cartilage remained similar over the course of the study; 87.5% of implants were reduced in size, and in 3 cases (12.5%), they were completely resorbed; 50% of the implants had a slightly hyperintense signal (relative to the normal meniscus), and signal intensity changes suggested that full maturation had occurred in 37.5% at final follow-up (based on the Genovese scores). The lateral CMI demonstrated that it was safe in this population study, with decreased pain and improved knee function in 96% of patients with excellent/good Lysholm results in 87% of patients at a minimum 2-year follow-up. The MRI scans demonstrated a decreased implant size relative to a normal meniscus.
Medical subject headings
- Knee Injuries
- Menisci, Tibial
- Tibial Meniscus Injuries
Anatomy
- knee
- tibia