Comparison of 12-hour urine protein and protein:creatinine ratio with 24-hour urine protein for the diagnosis of preeclampsia.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 22939731.
- Also identified by DOI 10.1016/j.ajog.2012.06.010.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this study was to evaluate the performance of the 12-hour urine protein >165 mg and protein:creatinine ratio >0.15 for the prediction of 24-hour urine protein of ≥300 mg in patients with suspected preeclampsia. We performed a prospective observational study of 90 women who had been admitted with suspected preeclampsia. Protein:creatinine ratio and 12- and 24-hour urine specimens were collected for each patient. Test characteristics for the identification of 24-hour urine protein ≥300 mg were calculated. A 12-hour urine protein >165 mg and protein:creatinine ratio of >0.15 correlated significantly with 24-hour urine protein ≥300 mg (r = 0.99; P < .001; and r = 0.54; P < .001, respectively). A 12-hour urine protein >165 mg performed better than protein:creatinine ratio as a predictor of a 24-hour urine protein ≥300 mg (sensitivity, 96% and 89%; specificity, 100% and 49%; positive predictive value, 100% and 32%; negative predictive value, 98% and 91%, respectively). The high correlation of a 12-hour urine protein >165 mg with a 24-hour urine protein ≥300 mg (with the benefit of a shorter evaluation time) and the high negative predictive value of protein:creatinine ratio suggest that the use of both these tests have a role in the evaluation and treatment of women with suspected preeclampsia.
Medical subject headings
- Creatinine
- Pre-Eclampsia
- Proteinuria