The effect of sample holder geometry on electromagnetic heating of nanoparticle and NaCl solutions at 13.56 MHz.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 22997262.
- Also identified by DOI 10.1109/TBME.2012.2219049.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Electromagnetic absorption and subsequent heating of nanoparticle solutions and simple NaCl ionic solutions is examined for biomedical applications in the radiofrequency range at 13.56 MHz. It is shown via both theory and experiment that for in vitro measurements the shape of the solution container plays a major role in absorption and heating.
Medical subject headings
- Nanoparticles
- Sodium Chloride