A multicenter, randomized, prospective, controlled study comparing sacrospinous fixation and transvaginal mesh in the treatment of posthysterectomy vaginal vault prolapse.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 23021692.
- Also identified by DOI 10.1016/j.ajog.2012.08.016.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The objective of the study was to compare recurrence and complication rates for sacrospinous fixation (SSF) and prolene mesh techniques for the primary treatment of posthysterectomy vaginal vault prolapse. Patients undergoing surgery for vault prolapse were included in a multicenter, randomized, controlled study comparing SSF or total mesh (Prolift; Gynecare/Ethicon, Somerville, NJ). The examination included pelvic organ prolapse quantification, urodynamics, ultrasound, and quality-of-life (QoL) questionnaires before and 3 and 12 months after surgery. Of 168 randomized patients, 83 underwent SSF and 85 mesh repair. Prolapse recurrence after 12 months occurred in 39.4% of the SSF group and in 16.9% of the mesh group (P = .003). The mesh exposure rate was 20.8%. No difference in QoL improvement as well as of de novo stress urinary incontinence and overactive bladder onset was found. Mesh exposure occurrence was balanced against a lower prolapse recurrence rate in the patients undergoing mesh surgery compared with those undergoing SSF.
Medical subject headings
- Hysterectomy
- Ligaments
- Pelvic Organ Prolapse
- Surgical Mesh
- Vagina