Effect of trabecular bone on the appearance of marrow in gradient-echo imaging of the appendicular skeleton.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 2305069.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This prospective study evaluated the effect of trabecular bone on the appearance of marrow in gradient-echo (GRE) images of the appendicular skeleton in vivo at high magnetic field strength. Magnetic resonance (MR) imaging of 10 normal extremities in five patients was performed with spin-echo (SE) and GRE sequences. The latter were obtained with gradient recalled acquisition in a steady state. SE and GRE sequences had identical spacing and planes of imaging. Cortical bone appeared as a signal void regardless of the pulse sequences and parameters. Marrow in contact with trabecular bone exhibited a shortened effective transverse relaxation time (T2*) and resultant signal loss because of local field inhomogeneities where mineralized matrix interfaced with it. This T2* effect was increased in regions with more trabecular bone (epiphysis) than regions with little trabecular bone (diaphysis). A low signal intensity on GRE images may represent fatty marrow with a high content of trabecular bone and should not be interpreted only as hematopoietic marrow.
Medical subject headings
- Bone Marrow
- Bone and Bones
- Extremities
- Magnetic Resonance Imaging